When encountering a Purple Screen of Death (PSOD) with the error message “NOT_IMPLEMENTED bora/vmkernel/main/world.c:2307” in VMware ESXi environments, this represents a known issue that frequently occurs on HPE server platforms. Fortunately, there’s a clear resolution available.
1. Root Cause Analysis : ESXi “NOT_IMPLEMENTED bora/vmkernel/main/world.c:2307”
The “NOT_IMPLEMENTED bora/vmkernel/main/world.c:2307” error primarily occurs on HPE Gen10, Gen10 Plus, and Gen11 platforms running VMware ESXi 7.0 and ESXi 8.0 or later versions.
Affected Environment
- Servers: HPE ProLiant Gen10/Gen10 Plus/Gen11 series
- Operating System: VMware ESXi 7.0, ESXi 8.0 or later
- Root Cause: HPE iLO Native driver compatibility issue
Component | Details |
---|---|
Affected Platforms | HPE Gen10/Gen10 Plus/Gen11 |
ESXi Versions | 7.0, 8.0 or later |
Error Type | Kernel Panic (PSOD) |
Root Cause | HPE iLO Native driver compatibility |
2. Primary Resolution – HPE iLO Driver Update
The most effective resolution is updating the HPE iLO Native driver to version 10.8.2 or later.
Driver Update Steps
Step 1: Check Current Driver Version
esxcli software vib list | grep -i ilo
Step 2: Download Latest HPE iLO Native Driver
- Download version 10.8.2 or later from HPE Support Center
- URL: HPE Support Center
Step 3: Install Driver
# Enter maintenance mode
vim-cmd hostsvc/maintenance_mode_enter
# Install VIB package
esxcli software vib install -v /path/to/hpe-ilo-driver.vib
# Reboot system
reboot
3. Workaround Solution – Temporary Fix
If immediate driver update isn’t feasible, consider this temporary workaround.
Remove Related Services
As a temporary measure, you can remove HPE AMS, iSUT, and iLORest applications, though this introduces certain functional limitations.
Services to Remove:
- HPE Agentless Management Service (AMS)
- HPE Intelligent System Tuning (iSUT)
- HPE iLORest
Workaround Impact:
- Limited OS/software/firmware updates via vLCM-HSM
- Restricted HPE SPP/SSP online update methods
- Loss of ESXi information visibility in iLO
4. General ESXi PSOD Troubleshooting
Immediate Actions When PSOD Occurs
Step 1: Collect Screen Information
- Photograph all error messages on PSOD screen
- Record backtrace information
Step 2: System Reboot
# Force reboot and set maintenance mode
vim-cmd hostsvc/maintenance_mode_enter
Step 3: Collect Core Dump
# Check core dump files
ls -la /vmfs/volumes/*/vmkdump/
5. Log Analysis & Diagnosis
Essential Log File Review
System Log Verification:
# Check VMkernel logs
tail -f /var/log/vmkernel.log
# Check host logs
tail -f /var/log/hostd.log
# Check warning logs
tail -f /var/log/vmkwarning.log
Hardware Status Inspection
Memory Testing:
# Check ESXi memory status
esxcli hardware memory get
CPU Status Verification:
# Check CPU information
esxcli hardware cpu list
6. Prevention & Monitoring
Regular Inspection Items
Inspection Item | Frequency | Command/Method |
---|---|---|
Driver Version | Monthly | esxcli software vib list |
Hardware Status | Weekly | HPE iLO interface check |
System Logs | Daily | /var/log/vmkernel.log review |
Monitoring Automation
# Automated health check script
#!/bin/bash
# check_esxi_health.sh
esxcli software vib list | grep -i ilo
esxcli hardware memory get | grep -i error
7. VMware Support Preparation
Required Information Collection
1. System Information
# ESXi version information
vmware -lv
# Hardware information
esxcli hardware platform get
2. Log Bundle Generation
# Generate support bundle
vm-support -w /vmfs/volumes/datastore1/
3. Error Reproduction Information
- Error occurrence timestamp
- Operations being performed
- Recent system changes
The “NOT_IMPLEMENTED bora/vmkernel/main/world.c:2307” error occurring on HPE servers can be resolved by updating the HPE iLO Native driver to version 10.8.2 or later. This is a known compatibility issue, so follow the systematic resolution steps outlined above. If the problem persists after driver updates, consider investigating other hardware components (memory, CPU, storage) as potential causes requiring additional hardware diagnostics. 🙂